Description
Applications:
- Control and protect universal pump
- Adopting liquid probe, float switch or pressure switch to control pump start and stop
- Applied for water supply by liquid level control through float switch or liquid probe
- Applied for booster by pressure control through pressure switch and pressure tank
- Applied for drainage by liquid level control through float switch or liquid probe
- Applied for sewage pump with piggy-back float switch
Control characteristic:
- Duplex pump control
- Main pump / standby pump automatically alternate
- Main pump / standby pump automatically switch against malfunction
- Standby pump participates running if required
Features:
- Pump last five faults record displaying
- Pump accumulative running time displaying
- Pump shaft anti-rust
- Present one passive dry contact point (BA port)
- Present RS485 port
- Remote control panel (Optional)
- Push button calibration
- LCD screen displaying pump running status
- Memory function when power off & recovery
- Signal transmission distance up to 1000m
- Overflow alarm for drainage application
- Pump start time delay (Time settable)
- Pump stop time delay (Time settable)
- WIFI module (Optional)
- A/B Pump operation enable or disable function
- LCD screen locked function under auto state (Settable)
Specifications:
MODEL
L922
L932
Main technical data
- Start type
- Qty of controlled pump
- Rated input voltage
- Rated output power
DOL (Direct on line)
Duplex Pump
AC220V/AC230V Single Phase
50HZ/60HZ
0.37kw-2.2kw 90.5hp-3hp)
3-4kw (4hp-5.5hp)
MAX MOTOR
Output 220V 1Ph
Full Load
Max (A)
Starting Current Max (A)
HP
KW
0.5
0.37
18A
90A
0.75
0.55
1.0
0.75
1.5
1.1
2.0
1.5
3.0
2.2
4.0
3.0
25A
125A
5.5
4.0
AC380V/AC400 Three Phase
50HZ/60HZ
0.75kw-4kw (1hp-5.5hp)
5.5kw-11kw (7.5-15hp)
15kw (20hp)
MAX MOTOR
Output 220V 1Ph
Full Load
Max (A)
Starting Current Max (A)
HP
KW
1.0
0.75
12A
60A
1.5
1.1
2.0
1.5
3.0
2.2
5.0
3.0
5.5
4.0
7.5
5.5
25A
125A
10.0
7.5
15.0
11.0
20.0
15.0
32A
160A
Protection Function
- Overload protection
- Pump stalled protection
- Dry run protection with sensor free
- Under voltage protection
- Over voltage protection
- Repeat start protection
- Over temperature protection
- Overload protection
- Pump stalled protection
- Dry run protection with sensor free
- Under voltage protection
- Over voltage protection
- Repeat start protection
- Open phase protection
- Phase reversal protection
- Three phase unbalance protection
- Over temperature protection
Main installation data
- Working temperature
- Working humidity
- Degree of protection
- Mounting type
- Unit dimension (L x W x H)
-25°C-- +55°C
20%--90%RH, no drips concreted
IP54
Wall mounting
300× 240×120mm
SET/CTN Packing Size
6 sets/ctn 69*58*46cm
Connectable sensors
Liquid probe (standard accessory) / Float switch / Pressure switch