Description
Triogen AOP offers the unique advanced oxidation treatment of commercial pool water. The process combines the disinfection and oxidation properties of Ozone and UV making Triogen AOP the most advanced pool water purification system available.
Applications:
- Commercial pools
- Hotel and club pools
- Sea lion and penguin pools
Benefits:
- Safely lower free chlorine residual with effective disinfection including chlorine resistant microorganisms.
- Chloramine destruction reduces “red eye” and irritation of skin and respiratory system.
- Significant improvement in water clarity and air clarity.
- Reduction of Trihalomethane (THM) levels.
- Compact unit footprint suitable for small plant rooms.
- Designed for maximum operator and bather safety.
- Low installation cost – minimal connections required.
- Proven advanced oxidation process system since 1999.
Main Features:
- Ongoing EU ozone biocide regulation compliant.
- Simple to install a skid-mounted packaged system.
- Ozone safely generated and injected under vacuum.
- Corona discharge modules designed for 10+ years operation.
- Segregated ozone contact and UV stage reactors.
- High intensity long-life low pressure 16,000 hour UV lamps.
- Air-cooled system with high humidity durability.
- Manual and remote operation status.
- CE certified, manufactured to ISO 9001 : 2015.
AOP Technology:
- Triogen AOP is a combination of ozone gas and UV light to form highly reactive hydroxyl radicals.
- Enhances the decomposition of organic pollutants.
- Offers excellent pathogen control through the inactivation of chlorine resistant organisms.
- The UV light will photochemically destroy any residual ozone in the water, removing the need for deozonation equipment.
- Triogen AOP is a unique and chemical-free technology operating under full vacuum, a result of 30 years experience in water treatment.
TECHNICAL DATA MODEL
Pool Volume
Bypass Flow Rate
Ozone Production
Feed Gas Production
Power Consumption
Power Supply
Weight (empty)
Weight(flooded)
m3
m3/h
g/h
ltr/min
kW
v/ph/Hz
kg
kg
AOP 150
150
6.0
6.0
5
1.3
230/1/50
160
240
AOP 300
300
12.5
12.5
5
1.89
230/1/50
255
405
AOP 600
600
25.0
25.0
10
3.69
400/3/50
490
790
AOP 900
900
37.5
37.5
15
5.49
400/3/50
725
1175
AOP 1200
1200
50.0
50.0
20
7.29
400/3/50
960
1560
AOP 1500
1500
62.5
62.5
25
9.09
400/3/50
1200
1950