Tornatech JPx Series Jockey Pump Controllers

Description

 

  • Designed to control jockey pumps which maintain water pressure in fire pump serviced systems.
  • Prevents unnecessary starting of the fire pump due to small leaks in the sprinkler system piping.

 

Standard Features:

 

All Models except Models DJP and DJD

  • HP rated fuse-less thru-the-door main disconnect switch.
  • iPD+ Operator Interface provides
    • Visual indicators
      • Manual motor run
      • Automatic motor run
      • System pressure
      • Automatic mode
      • Off mode
      • Motor overload
      • Pump start counter
      • Elapsed time meter (hours / non-resettable)
    • All adjustments on door front
      • Timers
        • Minimum run period timer
        • Sequential start timer
      • Operators
        • OFF-AUTO pushbutton
        • Start and stop pushbuttons.
  • Pressure transducer

 

Models JP1, JP2 and JP3

  • Accepts single power source
  • Controls one (1) jockey pump
  • JP1 = 120V/1Ph/60Hz
  • JP2 = 220V to 240V/1Ph/60Hz
  • JP3 = 200V to 600V/3Ph/50-60Hz
  • Thermo-magnetic motor protector
  • Across the line motor starter

 

Model JPY

  • Accepts single power source
  • Controls one (1) jockey pump
  • Only available for 200V to 600V/3Ph/50-60Hz (3-phase applications)
  • Thermo-magnetic motor protector
  • Wye-delta open transition motor starter

 

Model JPD

  • Accepts single power source
  • Controls two (2) pumps as LEAD-STANDBY (full redundancy)
  • Available for
    • 220V to 240V/1Ph/60Hz
    • 200V to 600V/3Ph/50-60Hz
  • Automatic alternation
  • Lead pump selector switch
  • Thermo-magnetic motor protectors (x2)
  • Across the line motor starters (x2)

 

Model JPV

  • Accepts single power source
  • Controls one (1) jockey pump
  • Only available for 200V to 600V/3Ph/50-60Hz (3-phase applications)
  • Variable Speed Drive with built-in motor protection

 

Model DJP

  • Accepts two separate power sources (i.e. normal & alternate)
  • Automatically connects to alternate power in case of normal power failure.
  • Controls one (1) pump
  • Only available for 200V to 600V/3Ph/50-60Hz (3-phase applications)
  • Hand-Off-Auto selector switch
  • Normal-Test selector switch
  • One automatic switchover device (transfer switch)
  • Visual indicators
    • Power On
    • Motor Run
    • Alternate power available
    • Normal power available
    • Connected to Normal position
    • Connected to Alternate position
  • Thermo-magnetic motor protectors (x2)
  • Across the line motor starters (x2)

 

Model DJD

  • Accepts two separate power sources (i.e. normal & alternate)
  • Automatically connects to alternate power in case of normal power failure.
  • Controls two (2) pumps as LEAD-STANDBY (full redundancy)
  • Only available for 200V to 600V/3Ph/50-60Hz (3-phase applications)
  • Hand-Off-Auto selector switch
  • Normal-Test selector switch
  • P1- AUTO-P2 lead pump selector switch
  • One automatic switchover device (transfer switch)
  • Visual indicators
    • Power On
    • Motor Run (x2)
    • Alternate power available
    • Normal power available
    • Connected to Normal position
    • Connected to Alternate position
  • Thermo-magnetic motor protectors (x2)
  • Across the line motor starters (x2)